- Version
- Download 312
- File Size 582.22 KB
- File Count 1
- Create Date 23/06/2023
- Last Updated 23/06/2023
Anti-GBM antibodies - possible false positives
We have received a field safety notice from our anti-GBM antibody assay manufacturer (Phadia), stating that their assay design 'may contribute to the identification of some false positive GBM results for specific samples containing anti-BSA antibodies'. This affects both weak and strong positive anti-GBM antibody results.
As a result we are now routinely sending all first time positive anti-GBM antibodies (results >10 U/mL) to Tayside Immunology laboratory for confirmation by immunoblot assay. Tayside have confirmed that they perform this immunoblot assay weekly.
We will continue to phone all first time positive anti-GBM antibody results to the requesting clinician/ward/external laboratory.
Further details are available within the attached letter available for download below. Please contact us if you have any further questions.
Attached Files
File | Action |
---|---|
GBM Service User Letter June 2023.pdf | Download |